摘要: |
目的 探讨反相HPLC法测定奈达铂和注射用奈达铂的含量和有关物质的可行性。方法 反相HPLC法检测5批奈达铂,3个规格7批注射用奈达铂的专属性与耐受性、线性关系、检出限、定量限、重复性与稳定性以及样品含量和有关物质。色谱条件:特定品牌C18柱;流动相为辛烷磺酸钠溶液-乙腈,流速1.0 mL/min,柱温40 ℃,检测波长220 nm。结果 奈达铂浓度为0.025~4.00 mg/mL浓度范围内,与峰面积线性关系良好(相关系数r=0.9998), 检出限为0.05036 μg/mL,定量限为0.1259 μg/mL。结论 反相HPLC法方法简便,结果准确,适用于对奈达铂和注射用奈达铂的质量控制。 |
关键词: 反相HPLC法 奈达铂和注射用奈达铂 含量测定 |
DOI:10.11724/jdmu.2016.06.07 |
分类号:R927.11 |
基金项目: |
|
Determination of the content and the related substances of Nedaplatin crude drug and its injection by RP-HPLC |
LU Jun, JIAO Jian, NIU Yu-juan
|
Dalian Institute for Drug Control, Dalian 116021, China
|
Abstract: |
Objective To establish a RP-HPLC method for determination of contents of Nedaplatin and its related substances in Nedaplatin injection.Methods The RP-HPLC condition was consisted of a specific brand C18 column (4.6 mm×250 mm, 5 μm) with a column temperature at 40 ℃, the mobile phase was octane sulfonic acid sodium solution (the right amount of 0.856 g octane sulfonic acid sodium dissolved by water, adding phosphate 0.5 mL diluted to 1000 mL)- acetonitrile (91∶[KG-*2]9) ,with a flow rate of 1.0 mL/min and detection at 220 nm.Results Nedaplatin showed good linearity in the range of 0.025-4.000 mg/mL (r=0.9998). The limit of detection and quantitation was 0.05036 μg/mL and 0.1259 μg/mL respectively.Conclusion The RP-HPLC method would be simple and applicable for the quality control of Nedaplatin crude drug and its injection. |