摘要: |
[摘要] 目的通过螺旋CT多期扫描对慢性尿路梗阻且血肌酐正常患者的分肾功能进行评估。方法 前瞻性研究65例单侧或双侧慢性上尿路梗阻并且血肌酐正常的成年患者,60例为单侧梗阻,对侧肾正常,其余5例为双侧梗阻。所有患者均行螺旋CT多期扫描及99mTc-DTPA核素肾动态显像检查。CT用来明确梗阻的原因,间接测定双肾的肾小球滤过率(GFR),分析梗阻肾脏CT GFR和同位素GFR之间的相关性。结果 梗阻肾脏同位素GFR为(36.9±9.79)mL/min,CT GFR为(37.8±10.53)mL/min,梗阻肾脏同位素GFR与相应的CT GFR之间呈显著正相关(r=0.74,P<0.001),其同位素GFR与CT GFR差异没有显著性意义(P=0.28);正常肾脏的同位素GFR为(62.3±13.07)mL/min,CT GFR为(62.1±10.11)mL/min,正常肾脏的同位素GFR和CT GFR比较,同样呈显著正相关(r= 0.78,P<0.001),其同位素GFR与CT GFR差异没有显著性意义(P=0.75)。结论 在梗阻肾脏及正常肾脏的功能评估中,螺旋CT多期扫描对于总肾功能和分肾功能的计算与核素肾动态显像一样准确。 |
关键词: 体层摄影术 发射型计算机 放射性核素 肾动态显像 肾小球滤过率 梗阻 |
DOI:10.11724/jdmu.2014.03.11 |
分类号: |
基金项目:基金项目:辽宁省自然科学基金项目(20082205) |
|
Value of contrast enhanced spiral computerized tomography for differential renal functional assessment in patients with chronic obstructive uropathy |
LIU Hao 1, JU Wen-bin 2, WANG Xiao-mei 3, TIAN Ai-juan 4, SUN Wei-bing 51,2,3,4,5
|
1.Seven-year Clinical Medicine,Dalian Medical University, Dalian 116044,China;2.Graduate School,Dalian Medical University, Dalian 116044,China;3.Department of Radiology Nuclear Medicine, the Second Affiliated Hospital of Dalian Medical University, Dalian 116027, China;4.Department of Nuclear Medicine, the Second Affiliated Hospital of Dalian Medical University, Dalian 116027,China;5.Department of Urology, the Second Affiliated Hospital of Dalian Medical University, Dalian 116027,China
|
Abstract: |
[Abstract] Objective To evaluate contrast enhanced spiral computerized tomography (CT) for differential renal functional assessment in the patients with chronic obstructive uropathy and normal serum creatinine. Methods We chose 65 patients with unilateral or bilateral chronic renal obstruction and normal serum creatinine in the prospective study. Sixty patients had unilateral obstruction and a normal contralateral kidney and the remaining five had bilateral obstruction. All patients underwent contrast enhanced spiral CT together with 99Tcmercaptoacetyltriglycine renal scan. CT was used to identify the cause of obstruction and selectively determine the glomerular filtration rate (GFR) of the differential kidneys. We analyzed the relationship between isotope GFR and CT GFR in the obstructed kidneys. Results The isotope GFR of obstructed kidneys was (36.9±9.79) mL/min,and the CT GFR was (37.8±10.53) mL/min. Comparison between the isotope GFR of obstructed kidneys with the corresponding CT GFR indicated a positive correlation (r=0.74,P<0.001). There was no statistically significant difference between isotope GFR and CT GFR in the obstructed kidneys (P=0.28). The isotope GFR of healthy kidneys was (62.3±13.07) mL/min,and the CT GFR was (62.1±10.11) mL/min. Moreover, similar to the obstructed kidneys, comparison between isotope GFR and CT GFR of normal kidneys showed an excellent correlation (r= 0.78,P<0.001). There was no statistically significant difference between isotope GFR and CT GFR in the healthy kidneys (P=0.75).Conclusion Contrast enhanced spiral CT is as accurate as radioisotope renal scan for calculating the total and differential kidney function in the functional assessment of the obstructive and healthy kidneys. |
Key words: [Key words] tomography, emission-computed radioactive nuclide, renal dynamic imaging glomerular filtration rate obstruction |