[目的]比较LASIK手术后厚、薄角膜瓣的视功能差异。[方法]收集行LASIK手术的患者46例(90只眼),其中薄瓣组(A组)24例(46只眼),厚瓣组(B组)22例(44只眼)。年龄18~38岁。屈光度为-1.50DS~-10.0DS。术前、术后均进行视力、屈光、波前相差、对比敏感度等视功能的检查。[结果]①术后1~6个月两组屈光度数差异无显著性意义(P>0.05);②波阵面像差:两组之间在Z3-3 、Z3-1 、Z31 、Z33 、Z40 、RMS3 、RMS4、RMS5、RMS6、RMSh方面差异没有显著性意义(P>0.05);③对比敏感度,两组之间差异无显著性意义(P>0.05)。[结论]屈光手术可以增加眼部的像差。但是,薄角膜瓣、厚角膜瓣组波阵面像差(Z3-3 、Z3-1 、Z31 、Z33 、Z40 、RMS3 、RMS4 、RMS5、RMS6、RMSh)差异没有显著性意义。两组的视功能无明显差异。 |
关键词: 角膜瓣 厚 薄 波阵面像差 对比敏感度 视力 |
DOI:10.11724/jdmu.2007.06.12 |
分类号: |
基金项目: |
|
Comparative study of visual function between different cornea flap after LASIK |
CHEN Li-na, ZHANG Feng-ju
|
Department of Ophthalmology, the First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
|
Abstract: |
[Objective]To compare visual function between thick and thin cornea flap after LASIK .[Methods]Forty-six cases (90 eyes) who had received LASIK were divided into the thin cornea flap group (46 eyes of 24 patients , group A)and the thick cornea flap group (44 eyes of 22 patients , group B). The age was ranging from 18 to 38 years old .The diopter was -1.50DS~-10.0DS.Inspection items included visual acuity (VA), refraction, wave-front analysis, contrast sensitivity during pre-and post-lasik1-6months.[Results]①. There was no difference for the refraction between the two groups after post-lasik 1-6 months ( P > 0.05).②Wave-front analysis :There was no difference between two groups in 、
Z3-3 、Z3-1 、Z31 、Z33 、Z40 、RMS3 、RMS4 、RMS5、RMS6、RMSh(P>0.05) .③ Contrast sensitivity :There was also no difference between two groups(P>0.05). Post-lasik one month:WOG: 72.9518(group A); 68.9412(group B) (P>0.05). WG: 125.51(group A); 107.2567 (group B) (P>0.05).
RED TEST : 125.1234(group A); 107.2567(group B) (P>0.05). READAPTION: 3.7667(group A); 4.2417 (group B) (P>0.05). Post-lasik 3-6month :WOG: 80.6573(group A); 69.8356(group B) (P>0.05).WG: 98.6176(group A); 96.2511(group B) (P>0.05).RED TEST: 150.6731(group A); 148.369(group B) (P>0.05).READAPTION: 4.1667(group A); 5.1258 (group B) (P>0.05).[Conclusions]LASIK can increase ocular aberrations .But there is no significant difference between thin and thick cornea flap group in Z3-3 、Z3-1 、Z31 、Z33 、Z40 ,RMS3,RMS4,RMS5,RMS6,RMSh.
Laisk with thin and thick cornea is safe and reliable. |